CEIA Power Cube Green Generators

CEIA Power Cube Green Generators

The CEIA Power Cube Green Generator Series is a high power Induction unit in a very compact size with embedded advanced microprocessor-based control software and state-of-the-art electronics. This allows high efficiencies (>96%) under various workload conditions while maintaining precise, stable, and repeatable output power. Due to its unique modular design, the Power Cube SA/400 Generator Series is available in several configurations to satisfy different user requirements.

The CEIA Power Cube Green Generator and Network Matching (Heating Head) hardware design combined with a state-of-the-art power and control electronics allow an extremely high conversion efficiency and, therefore a high reliability and low operating costs.

The embedded microprocessor control system is based on an extensive feedback signals network that allows a fine coil voltage and current control and guarantees the consistency and accuracy of output power generation, suitable for highly repeatable production processes.

All CEIA Power Cube Green Generators are equipped with an isolation transformer that separates the coil output from the power supply line guaranteeing a high level of operator safety.

Power Cube SA/400 Series Generators

Wideband Medium-High Frequency Green Generators

 

  • High power output
  • High level of performance with minimal operating costs
  • Automatic tracking & best optimization to load
  • Constant, repeatable power generation via microprocessor control
  • Minimum cooling water flow required
  • High safety: output insulation from the mains
  • Highly integrated with a small footprint
  • User friendly operations through graphical touch-screen interface
  • Stainless steel casing
  • Compliant with Electrical Safety and Electromagnetic Compatibility Regulations

 12.5-SA/40012.5-SA/400-2H2X12.5-SA/40025-SA/40025-SA/400-2H2X25-SA/40050-SA/400
Power Supply and PowerMax. input power12.5 kW12.5 kW2×12.5 kW25 kW25 kW2×25 kW50 kW
Max. power at inductor1000 kVAR1000 kVAR2x 1000 kVAR2000 kVAR2000 kVAR2x 2000 kVAR2000 kVAR
Power supply400 Vac ±10%, three-phase – 50 Hz / 60 Hz, no neutral
Input current23A max; external conductors 10 mm2 (min)46A max; external conductors 10 mm2 (min)85A max; external conductors 10 mm2 (min)
Frequency Range100 kHz… 400 kHz
CoolingWater cooling systemDirect off-take from mains at recommended pressure of approx. 4 bar (min. 2 bar, max. 8 bar)
Minimum flow rate: Generator: 2,5 litres per minute
Heating coil: 2 to 10 litres per minute, depending on the coil used
Water temperature at inlet: from ambient temperature to 45°C (non condensing)
Operating ModeContinuous operation
Control ModeAutomatic (controlled by a CEIA control and monitoring unit)
Control and MonitoringAutomatically stabilized heating power (not infl uenced by power supply voltage variations)
Self-DiagnosticVisual and acoustic fault signalMonitoring of cooling water temperature and flow
Monitoring for short-circuits in the heating conductor
Internal fault
Monitoring of inductor dimensioning
Monitoring of the heating head connection
Monitoring of the power supply voltage value
Operating ConditionsOperating temperature+ 5 °C to + 55 °C
Storage temperature– 20 °C to + 70 °C
Relative humidity0 – 95% (non condensing)
IP protection degreeIP54
Weight74 Kg79 Kg98 Kg97 Kg106 Kg170 Kg170 Kg
Safety FeaturesGalvanic isolation from the mains supply voltage
Complies with applicable international standards for Electrical Safety (EN 60204-1) and Electromagnetic Compatibility (EN 61000-6-2, EN 61000-6-4)

 

Power Cube SA/80 Series  Generators

Wideband Low-Medium Frequency 150, 100, 75, 50, 25 kW Green Generators

  • High Power output
  • High level of performance with minimal operating costs
  • Automatic tracking and best optimization to load
  • Constant, repeatable power generation via microprocessor control
  • Minimum cooling water flow required
  • High Safety: output insulation from the mains
  • Embedded digital electricity meter
  • Highly integrated with a small footprint
  • User Friendly Operations through graphical touch-screen interface
  • Stainless Steel casing
  • Compliant with Electrical Safety and Electromagnetic Compatibility Regulations

 Power Cube 25-SA/80Power Cube 50-SA/80Power Cube 75-SA/80Power Cube 100-SA/80Power Cube 150-SA/80
Power Supply and PowerMaximum absorbed power25 kW50 kW75 kW100 kW150 kW
Maximum power at inductor2000 kVAR (depends on type of head and inductor used)3000 kVAR (depends on type of head and inductor used)4000 kVAR (depends on type of head and inductor used)5000 kVAR (depends on type of head and inductor used)5000 kVAR (depends on type of head and inductor used)
Power supply400 V~, three-phase – 50 Hz / 60 Hz, no neutral
Input current45A max; external conductors 10 mm2 (min)85A max; external conductors 25 mm2 (min)130A max; external conductors 50 mm2 (min)170A max; external conductors 70 mm2 (min)255A max; external conductors 150 mm2 (min)
Frequency Range25 kHz…100 kHz
CoolingWater cooling systemDirect off-take from mains at recommended pressure of approx. 4 bar (min. pressure 2 bar, max. pressure 6 bar).
Minimum flow rate:
  • Generator: 2 liters per minute.
  • Heating head: from 3 to 10 liters per minute, depending on the coil used.

Water temperature at inlet: from ambient temperature to 45°C (non condensing)

Direct off-take from mains at recommended pressure of approx. 4 bar (min. pressure 2 bar, max. pressure 6 bar).
Minimum flow rate:
  • Generator: 2 liters per minute.
  • Heating head: from 5 to 20 liters per minute, depending on the coil used.

Water temperature at inlet: from ambient temperature to 45°C (non condensing)

Direct off-take from mains at recommended pressure of approx. 4 bar (min. pressure 2 bar, max. pressure 6 bar).
Minimum flow rate:
  • Generator: 3 liters per minute.
  • Heating head: from 8 to 25 liters per minute, depending on the coil used.

Water temperature at inlet: from ambient temperature to 45°C (non condensing)

Direct off-take from mains at recommended pressure of approx. 4 bar (min. pressure 2 bar, max. pressure 6 bar).
Minimum flow rate:
  • Generator: 3 liters per minute.
  • Heating head: from 8 to 30 liters per minute, depending on the coil used.

Water temperature at inlet: from ambient temperature to 45°C (non condensing)

Direct off-take from mains at recommended pressure of approx. 4 bar (min. pressure 2 bar, max. pressure 6 bar).
Minimum flow rate:
  • Generator: 3 liters per minute.
  • Heating head: from 8 to 30 liters per minute, depending on the coil used.

Water temperature at inlet: from ambient temperature to 45°C (non condensing)

Electric chiller systemPower: ≥ 5 kW
Water flow rate: 0,3 ÷ 0,8 m3/h
Pressure: 3.5 bar – 5 bar
Power: ≥ 10 kW
Water flow rate: 0,5 ÷ 1,5 m3/h
Pressure: 3.5 bar – 5 bar
Power: ≥ 15 kW
Water flow rate: 0,7 ÷ 1,7 m3/h
Pressure: 3.5 bar – 5 bar
Power: ≥ 20 kW
Water flow rate: 1,0 ÷ 2,0 m3/h
Pressure: 3.5 bar – 5 bar
Power: ≥ 30 kW
Water flow rate: 1,0 ÷ 2,0 m3/h
Pressure: 3.5 bar – 5 bar
Operating ModeContinuous operation
Control ModeAutomatic (controlled by a CEIA control and monitoring unit)
Control and monitoringAutomatically stabilized heating power (not influenced by power supply voltage variations)
Self-diagnosticsVisual and acoustic fault signalCooling water temperature and pressure monitoring
Short-circuits between inductor leads
Internal fault
Inductor dimensioning monitoring
Heating head connection monitoring
Power supply voltage value monitoring
Operating ConditionsOperating temperature+ 5 °C to + 55 °C
Storage temperature– 20 °C to + 70 °C
Relative humidity0 – 95% (non condensing)
IP Protection DegreeIP54
Weight132 Kg159 Kg270 Kg300 Kg500 Kg
Safety FeaturesGalvanic insulation from the mains supply voltage
Complies with international standards currently applicable for Electrical Safety (EN 60204-1) and Electromagnetic Compatibility (EN 61000-6-2, EN 61000-6-4)